| BOP.InletFlow | -311 |
| Plant Inlet CH4 | 1.2375 |
| RunStatus | OFF |
| BOP.PlantProdMeter | 0.01815 |
| BOP.PlantProdMeterTotal | 0.01202 |
| BOP.PlantEnergyTotal | 0.00026 |
| BOP.FieldVacuum | -15.119 |
| Product Gas O2 | 0.48285 |
| BOP.Status | 257 |
| Plant Running | OFF |
| Plant Producing | OFF |
| Plant in Standby | OFF |
| Screw Compressor 1 Running | Stopped |
| Screw Compressor 1 Producing | OFF |
| Screw Compressor 1 in Standby | OFF |
| Screw Compressor 2 Running | Stopped |
| Screw Compressor 2 Producing | OFF |
| Screw Compressor 2 in Standby | ON |
| Recip Compressor 1 Running | Stopped |
| Recip Compressor 1 Producing | OFF |
| Recip Compressor 1 in Standby | OFF |
| Recip Compressor 2 Running | Stopped |
| Recip Compressor 2 Producing | OFF |
| Recip Compressor 2 in Standby | ON |
| AIT-3939 O2% Flare Area | 0.3288 |
| AIT-4015 O2% Process Building | 0.98 |
| XT-LEL1 Methane Gas Detector at UOP Skid | 2.8882 |
| XT-LEL2 Methane Gas Detector at UOP Skid | 2.7647 |
| XT-LEL3 Methane Gas Detector at Refrigeration Skid | 2.7529 |
| XT-LEL4 Methane Gas Detector at Screw Compressor | 0 |
| XT-LEL5 Ammonia Gas Detector at Refrigeration Skid | 0 |
| XT-LEL6 Ammonia Gas Detector at UOP Chiller | 0 |
| XT-LEL7 Ammonia Gas Detector in Vent Line at Refrigeration Skid | -20.588 |
| XT-LEL8 Ammonia Gas Detector in Vent Line at UOP Chiller | 2.8529 |
| Screw Compressor 1 Suction Pressure | 0 |
| Screw Compressor 1 Discharge Pressure | 30 |
| Screw Compressor 1 Discharge Temperature | 30 |
| Screw Compressor 1 Oil Temperature | 20 |
| Screw Compressor 2 Suction Pressure | 20 |
| Screw Compressor 2 Discharge Pressure | 30 |
| Screw Compressor 2 Discharge Temperature | 0.9 |
| Screw Compressor 2 Oil Temperature | 0.6 |
| Recip Compressor 1 Oil Pressure | 0 |
| Recip Compressor 1 Oil Temperature | 1.1729 |
| Recip Compressor 1 1st Stage Suction Pressure | 0.97059 |
| Recip Compressor 1 1st Stage Suction Temperature | 2.5827 |
| Recip Compressor 1 1st Stage Discharge Pressure | 3.0627 |
| Recip Compressor 1 1st Stage Discharge Temperature | 0 |
| TT-4215 | 67.553 |
| Recip Compressor 1 2nd Stage Discharge Pressure | 1.2085 |
| Recip Compressor 1 2nd Stage Discharge Temperature | -0.04455 |
| XS-3914 Flare Run Status | Running |
| Flare Temperature | 1728.1 |
| PT-3919 Header Pressure | 84.856 |
| BL-02A Run Status | Stopped |
| BL-02B Run Status | Running |
| PV-3943 Waste Gas Line | ON |
| TIT-4444 Waste Gas Line Temperature | 51.169 |
| FT-4401 Waste Gas Flow | 0.06515 |
| FV-3930 Plant Inlet Valve | OFF |
| FT-3916 Plant Inlet Flow (MMSCFD) | -0.04455 |
| FT-3917 Flow Diverted to Flare | 2.2019 |
| Total Inerts | 100.39 |
| FIT-0616 | 0 |
| MMBTU/Day | 0 |
| Availability | 91 |
| PIT-0406 | 0 |
| PIT-0407 | 0 |
| TIT-0421 | 0 |
| TIT-0426 | 0 |
| TIT-0401 | 0 |
| TIT-0413 | 0 |
| TIT-0424 | 0 |
| TIT-0204 | 0 |
| TIT-0206 | 0 |
| TIT-0303 | 0 |
| TIT-0601 | 0 |
| TIT-0611 | 0 |
| TIT-0613 | 0 |
| TIT-0615 | 0 |
| TIT-0620 | 0 |
| PIT-0503 | 0 |
| PIT-0602 | 0 |
| PIT-0608 | 0 |
| PIT-0612 | 0 |
| PIT-0614 | 0 |
| PIT-0619 | 0 |
| FIT-0624 | 0 |
| PDIT-0304 | 0 |
| FIT-0610 | 0 |
| FIT-0621 | 0 |
| LT-0305 | 0 |
| TIT-0609 | 0 |
| PY-0410 | 0 |
| PY-0418 | 0 |
| PY-0409 | 0 |
| TY-0204 | 0 |
| TY-0206 | 0 |
| PY-0608 | 0 |
| LY-0306 | 0 |
| PY-0610A | 0 |
| Waste Gas CH4 | -0.0125 |
| Methane Recovery (%) | 0 |